MeterSense MDM
Smart meters need a smarter back office.
MeterSense checks interval reads before they reach a bill. A bad read gets caught and estimated in the back office, not found in a customer’s mailbox.
- Read
- Validate
- Rate
- Bill
- Pay
- Collect
37 of 38 reads validated1 estimated
418 Larchmont Ridge Rd
03:00 read: 48,000 gal in one hourmore than this meter can pass
Estimated from this meter's history: 0.4 gal
Correct bill goes out
| Item | Value |
|---|---|
| Water meters in the figure | 38 |
| Reads validated | 37 |
| Reads estimated | 1 |
| Estimated meter | MTR 40-118-227, 418 Larchmont Ridge Rd |
| Reported for the 03:00 hour | 48,000 gallons |
| Check failed | Maximum flow: more than a 5/8 inch meter can pass in an hour |
| Estimate | 0.4 gallons, the meter's 30-day average for 03:00 |
| Billing | Account 1027-48810-03 was billed on the estimated read |
| Gallons used for the bill, last 24 hours | 213.0 |
| Hour ending | Reported | Status | Used for the bill |
|---|---|---|---|
| 2026-10-12 04:00 | 0.4 | Validated | 0.4 |
| 2026-10-12 05:00 | 1.2 | Validated | 1.2 |
| 2026-10-12 06:00 | 6.8 | Validated | 6.8 |
| 2026-10-12 07:00 | 20.2 | Validated | 20.2 |
| 2026-10-12 08:00 | 24.5 | Validated | 24.5 |
| 2026-10-12 09:00 | 12.4 | Validated | 12.4 |
| 2026-10-12 10:00 | 5.8 | Validated | 5.8 |
| 2026-10-12 11:00 | 4.9 | Validated | 4.9 |
| 2026-10-12 12:00 | 6.4 | Validated | 6.4 |
| 2026-10-12 13:00 | 4.1 | Validated | 4.1 |
| 2026-10-12 14:00 | 3.6 | Validated | 3.6 |
| 2026-10-12 15:00 | 4.8 | Validated | 4.8 |
| 2026-10-12 16:00 | 7.9 | Validated | 7.9 |
| 2026-10-12 17:00 | 15.9 | Validated | 15.9 |
| 2026-10-12 18:00 | 28.4 | Validated | 28.4 |
| 2026-10-12 19:00 | 30.0 | Validated | 30.0 |
| 2026-10-12 20:00 | 17.5 | Validated | 17.5 |
| 2026-10-12 21:00 | 9.4 | Validated | 9.4 |
| 2026-10-12 22:00 | 5.2 | Validated | 5.2 |
| 2026-10-12 23:00 | 1.9 | Validated | 1.9 |
| 2026-10-13 00:00 | 0.6 | Validated | 0.6 |
| 2026-10-13 01:00 | 0.4 | Validated | 0.4 |
| 2026-10-13 02:00 | 0.3 | Validated | 0.3 |
| 2026-10-13 03:00 | 48,000 | Failed maximum-flow check | 0.4 (estimated) |
| Total used for the bill | 213.0 |
- 01Standard
- MultiSpeak 4.1
- Certified
- AMI head-endMeterSenseMDM
- No proprietary lock-in on meter data
- 02Head-ends
- 5+ AMI
- Head-End Integrations
- Head-end agnostic
- 03Daily reads
- Millions
- Daily Reads
- CollectValidateAnalyze
- Interval data, processed daily
Any Head-End. One Platform.
Itron, Sensus, Landis+Gyr, Aclara, Badger Meter. MeterSense connects to the AMI head-end systems your utility has deployed today. MultiSpeak 4.1 interoperability means no proprietary lock-in on meter data.
Validation Before the Bill Goes Out
Automated VEE (Validation, Estimation, Editing) catches anomalies before they become billing errors. Leak detection, zero-consumption alerts, and threshold monitoring protect both your revenue and your customer relationships.
Operational Intelligence, Not Just Data Storage
Consumption analytics, demand profiling, load curve analysis, and outage correlation. MeterSense gives your engineering and planning teams meter data management tools that turn raw interval data into insights they can act on.
Engineering
Grid stress analytics
Customer Service
Bill inquiry resolution
Field Ops
Tamper alerts
Planning
Load forecasting
“We deployed Sensus FlexNet across 65,000 endpoints. MeterSense was collecting and validating interval data within weeks. The billing team finally trusts the meter data coming in.”
Director of Engineering
Electric & Water Utility, Southeast US
MeterSense Questions
Explore More
Continue across the enQuesta platform
Ready to See What Reliable Looks Like?
Schedule a personalized demo and see how enQuesta handles your billing complexity, your integration requirements, and your timeline.